-40%
Fluke 116 Digital HVAC Multimeter with Temperature and Microamps
$ 97.41
- Description
- Size Guide
Description
Fluke 116 Digital HVAC Multimeter with Temperature and MicroampsProducts usually ship within 1 business day.
Key features
Digital multimeter designed specifically for HVAC professionals
Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)
Provides microamps to test flame sensors
Features low input impedance to helps prevent false readings due to ghost voltage
Presents a large white LED backlight for working in poorly lit areas
The Fluke 116 DMM provides the features you need to quickly troubleshoot HVAC equipment
The Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.
Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.
Other useful features:
Measures resistance, continuity, frequency, and capacitance
Provides Min/Max/Average to record signal fluctuations
Comes with a holster with probe holders for easy storage
Features a compact ergonomic design for one-handed operation
Fits into optional ToolPak™ magnetic hanger for hands-free operation
CAT III 600 V safety rated
What's in the box:
Fluke 116 Digital Multimeter
(1 pair) 4 mm silicone test lead set
80BK Integrated Temperature probe
Holster
Installed 9 V battery
Quick reference guide
Specifications
Maximum voltage between any terminal and earth ground:
600 V
Safety:
IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Display:
Digital: 6,000 counts, updates 4 per second
Bar Graph:
33 segments, updates 32 per second
Operating Temperature:
-10°C to +50°C
Storage Temperature:
-40°C to +60°C
Battery Type:
9 volt Alkaline, IEC 6LR61
Battery Life:
400 hours typical, without backlight
DC millivolts:
Range/Resolution
600.0 mV / 0.1 mV
Accuracy
±([% of reading] + [counts]): 0.5% + 2
DC volts:
Range/Resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy
±([% of reading] + [counts]): 0.5% + 2
Auto volts:
Range/Resolution
600.0 V / 0.1 V
Accuracy
2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMS
:
Range/Resolution
600.0 mV / 0.1 mV
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMS
:
Range/Resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity:
Range/Resolution
600 Ω / 1 Ω
Accuracy
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
Ohms:
Range/Resolution
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy
0.9% + 1
Range/Resolution
40.00 MΩ / 0.01 MΩ
Accuracy
5% + 2
Diode Test:
Range/Resolution
2.00 V / 0.001 V
Accuracy
0.9% + 2
Capacitance:
Range/Resolution
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy
1.9% + 2
Range/Resolution
> 1000 μF
Accuracy
5% + 20%
Lo-Z capacitance
:
Range
1 nF to 500 μF
Accuracy
10% + 2 typical
Temperature²
(Type-K thermocouple):
Range/Resolution
-40°C to 400°C / 0.1°C
Accuracy
1% + 10²
Range/Resolution
-40°F to 752°F / 0.2°F
Accuracy
1% + 18²
AC μA true-rms (45 Hz to 500 Hz)
:
Range/Resolution
600.0 μA / 0.1 μA
Accuracy
1.5% + 3
DC
μamps
:
Range/Resolution
600.0 μA / 0.1 μA
Accuracy
1.0% + 2
Hz (V or A input)²
:
Range/Resolution
99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz
Accuracy
0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.