-40%

FLUKE 1587 FC 2 IN 1 INSULATION MULTIMETER W FLUKE CONNECT 4692740 BRAND NEW!

$ 366.96

Availability: 144 in stock
  • Non-Domestic Product: No
  • Item must be returned within: 30 Days
  • Maximum Input Voltage: 1000V
  • Form Factor: Handheld
  • Modified Item: No
  • MPN: 4692740
  • DC Voltage Range: 1000V
  • Condition: New
  • Refund will be given as: Money Back
  • Country/Region of Manufacture: United States
  • Return shipping will be paid by: Buyer
  • Model: 1587FC
  • Display: Digital
  • Measurement Category: CAT IV
  • AC Voltage Range: 1000V
  • Restocking Fee: 20%
  • All returns accepted: Returns Accepted
  • Brand: Fluke
  • Features: Auto Power Off
  • Custom Bundle: No
  • Test/Measurement Functions: Frequency (Hz)

    Description

    SERIOUS BUYERS ONLY!
    PLEASE READ STORE DETAILS CAREFULLY!
    *** BRAND NEW ***
    FLUKE 1587 FC 2 IN 1 INSULATION MULTIMETER W FLUKE CONNECT
    PLEASE NOTE THE LAST 3 UNITS ARE MISSING THE PAPER SLEEVE THAT GOES AROUND THE HARD CARRYING CASE, IT WAS LOST DURING TRANSPORT. WE ARE CURRENTLY WAITING TO RECEIVE 3 NEW SLEEVES FROM THE SUPPLIER.
    Item Details:
    Manufacturer:
    FLUKE
    Description from Manufacturer:
    The high-performance 2-in-1 insulation DMM
    The Fluke 1587 FC Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
    The Fluke 1587 FC Insulation Multimeter adds four powerful new diagnostic functions through the Fluke Connect® Measurements app:
    PI/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
    Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
    Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
    Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets
    Product highlights
    PI/DAR timed ratio tests
    Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
    VFD low-pass filter for accurate motor drive measurements
    Auto-discharge of capacitive voltage for added user protection
    Insulation test (1587 FC: 0.01 MΩ to 2 GΩ)
    Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V, 1000 V) for many applications
    AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (Ω), Continuity
    Capacitance, diode test, temperature, Min/Max, frequency (Hz)
    Auto power off to save battery power
    CAT III 1000 V, CAT IV 600 V measurement category
    Large display with backlight
    Rugged, utility hard case allows you to bring everything you need for the job
    Included accessories: Remote probe, test leads and probes, alligator clips, K-type thermocouple
    Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient hands free operation
    Three-year standard warranty;
    Features:
    PI/DAR measurements with TrendIt™ graphs
    Memory storage through Fluke Connect Measurements app
    Temperature Compensation through Fluke Connect Measurements app
    VFD low-pass filter for accurate motor drive measurements
    Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
    Insulation test: 0.01 MΩ to 2.0 GΩ
    Auto-discharge of capacitive voltage
    Insulation test smoothing reading
    Frequency
    Capacitance
    Diode test
    Temperature
    Min/Max
    AC/DC Voltage
    DC Millivolts
    AC/DC Milliamps
    Resistance (0.1 Ω to 50 MΩ)
    Continuity
    Three-year warranty
    Remote probe, test leads, alligator clips
    K-type thermocouple
    Rugged, utility hard case
    Auto power off
    Sepcifications:
    Electrical Specifications
    AC voltage measurement
    Range
    600.0 mV
    Resolution
    0.1 mV
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)
    ±(1% + 3)
    Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)
    ±(2% + 3)
    6.000 V
    Resolution
    0.001 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)
    ±(1% + 3)
    Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)
    ±(2% + 3)
    60.00 V
    Resolution
    0.01 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)
    ±(1% + 3)
    Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)
    ±(2% + 3)
    600.0 V
    Resolution
    0.1 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)
    ±(1% + 3)
    Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)
    ±(2% + 3)¹
    1000 V
    Resolution
    1 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)
    ±(2% + 3)
    Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)
    ±(2% + 3)¹
    ¹ 1 kHz bandwidth
    Low-Pass Filter Voltage
    Range
    600.0 mV
    Resolution
    0.1 mV
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)
    ±(1% + 3)
    Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)
    +(2% + 3), -(6% - 3)
    6.000 V
    Resolution
    0.001 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)
    ±(1% + 3)
    Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)
    +(2% + 3), -(6% - 3)
    60.00 V
    Resolution
    0.01 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)
    ±(1% + 3)
    Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)
    +(2% + 3), -(6% - 3)
    600.0 V
    Resolution
    0.1 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)
    ±(1% + 3)
    Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)
    +(2% + 3), -(6% - 3)
    1000 V
    Resolution
    1 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)
    ±(2% + 3)
    Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)
    +(2% + 3), -(6% - 3)
    DC Voltage Measurement
    Range
    Resolution
    Accuracy ±(% of Rdg + Counts)
    6.000 V dc
    0.001 V
    ±(0.09% + 2)
    60.00 V dc
    0.01 V
    ±(0.09% + 2)
    600.0 V dc
    0.1 V
    ±(0.09% + 2)
    1000 V dc
    1 V
    ±(0.09% + 2)
    Input impedance
    10 MΩ (nominal), <100 pF
    Normal mode rejection ratio
    >60 dB @ 50 Hz or 60 Hz
    Common mode rejection ratio
    >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
    Accuracies apply to ± 100% of range
    DC Millivolts Measurement
    Range
    Resolution
    Accuracy ±(% of Rdg + Counts)
    600.0 mVdc
    0.1 mV
    ±(0.1% + 1)
    DC and AC Current Measurement
    AC 45 Hz to 1000 Hz
    Range
    400 mA
    Resolution
    0.1 mA
    Accuracy ±(% of Rdg+Counts)
    ±(1.5% + 2)¹
    Burden voltage (Typical)
    2 mV/mA
    Range
    60 mA
    Resolution
    0.01 mA
    Accuracy ±(% of Rdg+Counts)
    ±(1.5% + 2)¹
    Burden voltage (Typical)
    2 mV/mA
    DC
    Range
    400 mA
    Resolution
    0.1 mA
    Accuracy ±(% of Rdg+Counts)
    ±(0.2% + 2)
    Burden voltage (Typical)
    2 mV/mA
    Range
    60 mA
    Resolution
    0.01 mA
    Accuracy ±(% of Rdg+Counts)
    ±(0.2% + 2)
    Burden voltage (Typical)
    2 mV/mA
    Overload
    600 mA for 2 minutes maximum
    Fuse protection for mA input
    0.44 mA, 1000 V, IR 10 kA
    AC conversion
    Inputs are ac-coupled and calibrated to the rms value of sine wave input
    Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
    ¹ 1 kHz bandwidth
    Ohms Measurement
    Range
    Resolution
    Accuracy +(% of Rdg+Counts)¹
    600.0 Ω
    0.1 Ω
    ±(0.9% + 2)
    6.000 kΩ
    0.001 kΩ
    ±(0.9% + 2)
    60.00 kΩ
    0.01 kΩ
    ±(0.9% + 2)
    600.0 kΩ
    0.1 KΩ
    ±(0.9% + 2)
    6.000 MΩ
    0.001 MΩ
    ±(0.9% + 2)
    50.0 MΩ ²
    0.01 MΩ
    ±(1.5% + 3)
    Overload protection
    1000 V rms or dc
    Open circuit test voltage
    <8.0 V dc
    Short circuit current
    <1.1 mA
    ¹ Accuracies apply from 0% to 100% of range
    ² Up to 80% relative humidity
    Diode Test
    Diode test indication
    Display voltage drop: 0.6 V at1.0 mA nominal test current:
    Accuracy
    ±(2% + 3)
    Continuity Test
    Continuity indication
    Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
    Open circuit voltage
    <8.0 V
    Short circuit current
    1.0 mA typical
    Overload protection
    1000 V rms
    Response time
    >1 m sec
    Frequency Measurement
    Range
    Resolution
    Accuracy ±(% of Rdg+Counts)
    99.99 Hz
    0.01 Hz
    ±(0.1% + 1)
    999.9 Hz
    0.1 Hz
    ±(0.1% + 1)
    9.999 kHz
    0.001 kHz
    ±(0.1% + 1)
    99.99 kHz
    0.01 kHz
    ±(0.1% + 1)
    Frequency Counter Sensitivity
    600.0 mV ac
    V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz
    100.0 mV
    V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
    150.0 mV
    DC Trigger Levels¹ to 20 kHz²
    NA
    6.0 V
    V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz
    1.0 V
    V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
    1.5 V
    DC Trigger Levels¹ to 20 kHz²
    -400.0 mV and 2.5 V
    60.0 V
    V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz
    10.0 V
    V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
    36.0 V
    DC Trigger Levels¹ to 20 kHz²
    1.2 V and 4.0 V
    600.0 V
    V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz
    100.0 V
    V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
    -
    DC Trigger Levels¹ to 20 kHz²
    12.0 V and 40.0 V
    1000.0 V
    V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz
    300.0 V
    V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
    -
    DC Trigger Levels¹ to 20 kHz²
    12.0 V and 40.0 V
    ¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
    ² Usable to 100 kHz with full scale input
    Capacitance
    Range
    Resolution
    Accuracy ±(% of Rdg+Counts)
    1000 nF
    1 nF
    ±(1.2% + 2)
    10.00 μF
    0.01 μF
    ±(1.2% + 2)
    100.0 μF
    0.1 μF
    ±(1.2% ±90 counts)
    9999 μF
    1 μF
    ±(1.2% ±90 counts)
    Temperature Measurement
    Range
    Resolution
    Accuracy ±(% of Rdg+Counts)¹
    -40 ° C to 537 ° C
    0.1 °C
    ±(1% + 10 counts)
    -40 ° F to 998 ° F
    0.1 °F
    ±(1% + 18 counts)
    ¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
    Insulation Specifications
    Measurement range
    0.01 MΩ to 2 GΩ
    Test voltages
    50, 100, 250, 500, 1000 V
    Test voltage accuracy
    +20%, -0%
    Short-circuit test current
    1 mA nominal
    Auto discharge
    Discharge time <0.5 second for C = 1 μF or less
    Live circuit detection
    Inhibit test if terminal voltage > 30 V prior to initialization of test
    Maximum capacitive load
    Operable with up to 1 μF load
    Output Voltage
    50 V (0% to +20%)
    Display range
    0.01 to 6.00 MΩ
    Resolution
    0.01 MΩ
    Test current
    1 mA @ 50 kΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(3% + 5 counts)
    Display range
    6.0 to 50.0 MΩ
    Resolution
    0.1 MΩ
    Test current
    1 mA @ 50 kΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(3% + 5 counts)
    100 V (0% to +20%)
    Display range
    0.01 to 6.00 MΩ
    Resolution
    0.01 MΩ
    Test current
    1 mA @ 100 kΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(3% + 5 counts)
    Display range
    6.0 to 60.0 MΩ
    Resolution
    0.1 MΩ
    Test current
    1 mA @ 100 kΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(3% + 5 counts)
    Display range
    60 to 100 MΩ
    Resolution
    1 MΩ
    Test current
    1 mA @ 100 kΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(3% + 5 counts)
    250 V (0% to +20%)
    Display range
    0.1 to 60.0 MΩ
    Resolution
    0.1 MΩ
    Test current
    1 mA @ 250 kΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(1.5% + 5 counts)
    Display range
    60 to 250 MΩ
    Resolution
    1 MΩ
    Test current
    1 mA @ 250 kΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(1.5% + 5 counts)
    500 V (0% to +20%)
    Display range
    0.1 to 60.0 MΩ
    Resolution
    0.1 MΩ
    Test current
    1 mA @ 500 kΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(1.5% + 5 counts)
    Display range
    60 to 500 MΩ
    Resolution
    1 MΩ
    Test current
    1 mA @ 500 kΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(1.5% + 5 counts)
    1000 V (0% to +20%)
    Display range
    0.1 to 60.0 MΩ
    Resolution
    0.1 MΩ
    Test current
    1 mA @ 1 MΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(1.5% + 5 counts)
    Display range
    60 to 600 MΩ
    Resolution
    1 MΩ
    Test current
    1 mA @ 1 MΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(1.5% + 5 counts)
    Display range
    0.6 to 2.0 GΩ
    Resolution
    100 MΩ
    Test current
    1 mA @ 1 MΩ
    Resistance accuracy ±(% of Rdg + Counts)
    ±(10% + 3 counts)
    General Specifications
    Maximum voltage applied to any terminal and common
    1000 V
    Storage temperature
    -40 °C to 60 °C (-40 °F to 140 °F)
    Operating temperature
    -20 °C to 55 °C (-4 °F to 131 °F)
    Temperature coefficient
    0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
    Relative humidity
    Noncondensing
    0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
    0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
    0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
    Vibration
    Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
    Radio frequency communication
    2.4 GHz ISM Band
    Radio frequency certification
    FCC: T68-FBLE, IC: 6627A-FBLE
    Electromagnetic Compatibility
    International
    IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
    Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
    Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
    Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
    Korea (KCC)
    Class A Equipment (Industrial Broadcasting & Communication Equipment)
    Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
    USA (FCC)
    47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
    Enclosure protection
    IEC 60529: IP40 (non-operating)
    Safety
    IEC 61010-1
    Pollution Degree 2
    IEC 61010-2-033
    CAT IV 600 V / CAT III 1000 V
    Batteries
    Four AA batteries (NEDA 15A or IEC LR6)
    Battery life
    Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
    Size (H x W x L)
    5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
    Weight
    550 g (1.2 lb)
    Altitude
    Operating
    2000 m
    Storage
    12,000 m
    Over-range capability
    110% of range except for capacitance which is 100%
    Frequency overload protection
    <107 V Hz
    Fuse protection for mA input
    0.44A, 1000 V, IR 10 kA
    Includes:
    Remote probe
    Test leads
    Alligator clips
    K-type thermocouple
    Hard case
    User documentation
    Condition:
    NEW
    Auction Details:
    Shipping:
    All
    domestic
    packages will be shipped out via Fedex, UPS, or USPS within the lower 48 states
    Free shipping is through most economic option
    Shipping to Hawaii Puerto Rico Alaska costs extra, email us for shipping quote and those shipments will be shipped out via USPS priority mail, unless otherwise stated in the auction or negotiated in emails.
    Shipping to APO, RR, or PO box will be handled via USPS and would be extra on certain items, please email us prior bidding.
    Goods will be dispatched the latest in
    2
    business days.
    Goods will be shipped out after the holidays and weekends.
    No local pick
    ups accepted at this time, unless otherwise stated in the auction
    Shipping costs are set at that price to cover some of our costs and packaging and handling fees as well as some of the ebay and paypal fees which add to about 13% of the total end price. Please don't email us to negotiate about the shipping costs.  We are extremely busy, so we might not answer your emails.
    Shipping and handling fees are not negotiable, by bidding on this item the buyer agrees to pay for all the shipping costs
    We ship to any destination in the world.
    INTERNATIONAL BUYERS:
    The International shipping rate is flat rate to most destinations in the world, please email us for additional information.
    California buyers are subject to pay 9% tax.
    International  buyers are responsible for all tax and custom duty charges outside the country.
    Payment:
    U.S. Buyers:
    Credit cards through PayPal
    Please note that we can't accept direct credit card payments at this time
    International Buyers:
    PayPal or Wire
    Payment is due within 6 days of auction closing.
    If payment is not received within this time unless otherwise stated or negotiated, item will be relisted on eBay.
    Terms & Conditions:
    After the auction is closed,
    auction winners should contact us regarding any questions or requests.
    After the auction is closed, payment should be received within 6 days.
    Buyer has 30 days to return the product, return product should be brand new with all original accessories, buyer pays shipping costs.
    Shipping and handling charges are not returnable
    Items will be replaced or exchanged in case of DOA
    If the same item or similar item is not in stock in case of DOA, the buyer will receive a refund back
    We combine shipping to save customers money, however, there will be an additional charge per item, please read the description for each item to find out about the specific fees.
    All buyers are subject to pay all taxes and duty fees inside and outside of the United States,
    Our facilities are closed during the weekends and other holidays and there will be no shipments during these time periods. All packages will go out after the weekend or after the holidays.
    Contact Information:
    Please use ebay message